HOME
JK-GROUP
JK-GROUP
NEWS
Audio Guide
SERVICE CLOTHES
EDGE CONNECTORS PCB
CERTIFICATION
SERVICE CHECK
PRESS
TECHNOLOGY
TEAM VIEWER
Studio Manager
System MESSAGES
Wellsystem
Ergoline/Soltron
OPERATING INSTRUCT
up to 2003
from 2003
PLANNING MANUAL
INTERNAL
WELLSYSTEM
SERVICE PC
Software Pool
Voice Guide
TEAM VIEWER
DSI-Measurement
Galep Software
SYSTEM MESSAGES
SERVICE PC
USB-DONGLE
SERVICE INFORMATION
Virobuster
Soltron
Ergoline
WIRING DIAGRAMS 22-300
EQUIPMENT NEWS
NEW TK 8000
AMBITION / XS
MULTIVISION
Tools/Touch Up paints
Equipment SOFTWARE
TRAINING
FOLDER UPDATE
REF. GUIDE WELLSYSTEM
REF. GUIDE IQ-TECHNOLOGY
CBT TRAINING
DATES
ERGOLINE TRAINING
SOLTRON TRAINING
WELLSYSTEM TRAINING
GLOBALPOINTS
JK-OFFICEPOINT
JK-INFOPOINT
JK-DOKUPOINT
JK-ASSEMBLYPONT
Virobuster
Soltron
Ergoline
Beauty Angel
CONTACT
IMPRINT
PHONE & FAX
HOME
»
TECHNOLOGY
»
SYSTEM MESSAGES
»
ERGOLINE/SOLTRON
»
ERGOLINE/SOLTRON SYSTEM MESSAGES
ADDRESS
JK-INTERNATIONAL GMBH
DIVISION JK-GLOBAL SERVICE
KÖHLERSHOHNER STRASSE
D-53578 WINDHAGEN
TEL: 0049-2224-818-879
FAX: 0049-2224-818-205
Contact
ERGOLINE/SOLTRON MESSAGES
System messages of all Ergoline and Soltron units
Here a list of all system messages by Soltron and Ergoline units!
For more - please log in to the protected area. You`ll find detailed information in "INTERNAL/SYSTEM MESSAGES".
E001
Warning: condensate tank full
E002
Warning: exhaustion of condensed water defective
E003
System message: overpressure switch air conditioning system
E004
System message: pressure sensor higher than 25 bar
E005
Warning: temperature fuse body heating
E006
Warning: temperature sensor body air
E010
System message: temperature fuse facial tanner
E011
System message: temperature fuse for canopy
E012
System message: temperature fuse for base
E013
System message: air outlet temperature sensor for canopy
E014
System message: air inlet temperature sensor
E015
System message: temperature sensor air circulation for unit’s cooling
E016
System message: temperature sensor capacitor air conditioning system
E017
System message: temperature sensor air inlet
E018
System message: lamp temperature < room temperature
E019
System message: lamp temperature > room temperature + 30° C / 86° F
E020
System message: filter glass facial tanner (canopy centre and rear)
E021
System message: filter glass facial tanner (canopy in front)
E022
System message: filter glass facial tanner (side section)
E023
System message: filter glass facial tanner (canopy - side section)
E024
System message: filter glass facial tanner (canopy centre, rear, front)
E025
System message: filter glass facial tanner (canopy centre, rear, front and side section)
E027
System message: filter glass facial tanner (canopy rear)
E028
System message: filter glass facial tanner (canopy centre)
E029
Warning message: Timeout inspection of the high pressure units
E030
System message: safety switch acrylic panel canopy (or glass decor canopy Avantgarde)
E031
System message: safety switch acrylic panel base or tank base
E032
System message: safety switch acrylic panel (canopy - side section – base – tank - shoulder tanner)
E034
System message: safety switch acrylic panel (canopy – side section – base – tank - shoulder tanner)
E035
System message: safety switch acrylic panel (canopy – base – side section or shoulder tanner)
E036
System message: safety switch acrylic panel base or tank base
E037
System message: safety switch acrylic panel canopy or side section
E038
System message: safety switch acrylic panel base or tank base
E039
System message: safety switch acrylic panel shoulder tanner
E040
System message: air flow switch has not turned on
E041
System message: air flow switch has not turned off
E042
Warning: air flow switch has not turned on (increasing rotation speed by 10%)
E050
System message: safety switch front panel front (top)
E051
System message: safety switch rear panel rear (top)
E052
System message: opening mechanism arm > 45 seconds
E053
System message: filter glass high-pressure units upper body (3-4-5-8-9-10)
E054
System message: filter glass high-pressure units lower body (1-2-6-7)
E055
System message: malfunction high-pressure unit 1(front)
E056
System message: malfunction high-pressure unit 2 (rear)
E057
System message: malfunction high-pressure unit (front)
E058
System message: malfunction high-pressure unit (centre)
E059
System message: malfunction high-pressure unit (rear)
E060
System message: malfunction high-pressure unit (side section)
E061
System message: safety switch acrylic panel and canopy cover
E062
System message: safety switch acrylic panel base and side section
E063
System message: safety switch acrylic panel side section
E064
System message: safety switch cover
E065
System message: safety switch acrylic panel canopy
E070
System message: malfunction high-pressure unit (1) foot (front)
E071
System message: malfunction high-pressure unit (2) foot (centre)
E072
System message: malfunction high-pressure unit (3) foot (rear)
E073
System message: malfunction high-pressure unit (4) foot (side section)
E074
System message: malfunction high-pressure unit (5) legs (front)
E075
System message: malfunction high-pressure unit (6) legs (centre)
E076
System message: malfunction high-pressure unit (7) legs (rear)
E077
System message: malfunction high-pressure unit (8) legs (side section)
E078
System message: malfunction high-pressure unit (9) body (front)
E079
System message: malfunction high-pressure unit (10) body (centre)
E080
System message: malfunction high-pressure unit (11) body (rear)
E081
System message: malfunction high-pressure unit (12) body (side section)
E082
System message: malfunction high-pressure unit (13) upper body (front)
E083
System message: malfunction high-pressure unit (14) upper body (centre)
E084
System message: malfunction high-pressure unit (15) upper body (rear)
E085
System message: malfunction high-pressure unit (16) upper body (side section)
E090
System message: emergency switch-off time exceeded
E091
System message: I²C-Bus transmission error
E092
System message: wiring power error in the safety chain
E095
System message: additional controller
E100
System message: emergency switch-off time exceeded
E101
System message: I²C-Bus transmission error
E102
System message: wiring power error in the safety chain
E103
Warning: malfunction audio unit
E104
System message: chip card error
E105
System message: additional controller
E106
System message: heating controller
E107
System message: controller facial tanner
E108
System message: malfunction rotation speed control 1
E109
System message: malfunction rotation speed control 2
E110
Warning: Aroma / Aqua-Fresh Controller
E111
Warning: Audio amplifier
E112
Warning: channel choice
E113
System message: malfunction real-time clock
E114
System message: malfunction equipment pass / parameter memory
E115
System message: electronic ballasts / lamp ballasts control PCB
E116
System message: high-pressure fan control PCB
E119
System message: malfunction data communication cockpit control
E120
System message: malfunction skin type measurement
E121
System message: calibration required
E122
System message: calibration failed
E123
System message: validation failed
E124
System message: data communication with the sensor defective
E125
Warning: tanning in normal mode
E126
System message: power supply voltage
E128
System message: undervoltage
E130
System message: equipment mistake of the PCB slot
E131
System message: data communication additional controller
E132
System message: start-up inspection of the UV sources
E133
System message: switch function additional controller rotation speed control
E134
System message: malfunction fuse rotation speed
E135
System message: malfunction power supply rotation speed control
E140
System message: malfunction main conductor does not switch on
E141
System message: malfunction main conductor does not switch off
E142
System message: malfunction switch-on cycle main conductor
E143
System message: malfunction difference coin box input
E150
System message: malfunction high-pressure unitsA 1-3
E151
System message: malfunction high-pressure unitsA 4-6
E152
System message: malfunction high-pressure unitsB 7-9
E153
System message: malfunction high-pressure unitsB10-12
E154
System message: malfunction high-pressure unitsC13-15
E155
System message: malfunction high-pressure unitsC16-18
E156
System message: malfunction high-pressure unitsD19-21
E157
System message: malfunction high-pressure unitsD22-24
E158
System message: malfunction high-pressure unitsE25-27
E159
System message: malfunction high-pressure unitsE28-30
E160
em message: malfunction acrylic panel high-pressure units A 1-6
E161
System message: malfunction acrylic panel high-pressure units B 7-12
E162
System message: malfunction acrylic panel high-pressure units C 13-18
E163
System message: malfunction acrylic panel high-pressure units D 19-24
E164
System message: malfunction acrylic panel high-pressure units E 25-30
E165
System message: malfunction high-pressure units 1-3 (left side)
E166
System message: malfunction high-pressure units 5-7 (right side)
E167
System message: malfunction high-pressure unit 4 (left side)
E168
System message: malfunction high-pressure unit 8 (right side)
E170
System message: Power Supply of the fan control input at the main baord is missing
E190
Warning: missing language in the cockpit control
E191
Warning: missing language in the audio controller
E192
System message: Timer mode activated
E200
Warning: malfunction fan electronic component board
E202
System message: error during software update
25b
Warning: pressure of air condition above 25 bar
40°C
Warning: air input temperature above 40° C / 104° F
50°C
Warning: air circulation or lamp temperature above 50 °C / 122° F
DOOR
Warning: upright tanner’s door open