- E501 Error reading or writing on the EEPROM
- E502 Error configuring the control panel
- E503 (Open) Safety chain open
- E516 Error starting the frequency converter pump
- E517 Frequency converter pump voltage Vdd too low
- E518 Frequency converter pump voltage Vdd too high
- E519 Frequency converter pump temperature too low
- E520 Frequency converter pump temperature too high
- E521 Frequency converter pump voltage Umess IZW too low
- E522 Frequency converter pump voltage Umess IZW too high
- E523 Frequency converter pump intermediate circuit voltage Uzw too low
- E524 Frequency converter pump intermediate circuit voltage Uzw too high
- E525 Frequency converter pump ripple voltage too high
- E526 Frequency converter pump motor current too high
- E527 Frequency converter pump intermediate circuit voltage Uzw mit PFC too low.
- E528 Frequency converter pump intermediate circuit voltage Uzw with * PFC too high
- E529 Frequency converter pump motor current too low (pump blocked)
- E530 WARNING: Frequency converter pump temperature has reached prewarning level
- E531 Faulty communication between frequency converter pump and process control unit
- E532 Frequency converter pump current loop interrupted
- E548 Water temperature too low < 0°C
- E549 Water temperature too high > 80°C
- E550 Interruption temperature safety chain
- E551 Warning threshold water temperature >42°C has been reached
- E564 Nozzle unit motor gives no impulses during reference movement
- E565 Nozzle unit motor gives various impulses according to the direction during reference mo-vement (mechanical slip)
- E566 Reference movement is not terminated within waiting time.
- E568 Nozzle unit motor is switched off due to constant overcurrent supply
- E569 Nozzle unit does not stopp within waiting time
- E570 Nozzle unit does not start (single movement)
- E571 Nozzle unit does not reach destination within waiting time
- E572 Nozzle unit does not start (pendular movement)
- E573 Nozzle unit does not shuttle any more
- E574 Motor control card cannot be adjusted (software of motor control card out of date)
- E575 Nozzle unit does not reach limit switch within waiting time
- E576 Nozzle unit does not drive as expected
- E580 Something has been plugged into the card reader but it cannot be approached (card turned)
- E581 No massage programme has been recorded
- E582 Error writing on the card
- E583 Card cannot be written on
- E600 Timer for activity control on the I²C bus has run out
- E602 I²C bus communication with RTC component faulty
- E603 I²C bus communication with control panel faulty
- E604 I²C bus communication with motor control card faulty
- E605 I²C bus communication with EEPROM component faulty
Legend
- FU = Frequency converter
- Vdd = Internal voltage in the frequency converter. This value cannot be measured from outside.
- Umess IZW = Internal voltage in the frequency converter. This value cannot be measured from outside.
- Uzw = Internal voltage in the frequency converter. This value cannot be measured from outside.
- STB = Temperature limiter 50°C
- I²C Bus = Bus system for communication between control and the inserted components
- Izw = Current in the intermediate circuit
- RTC = Internal components of the frequency converter
- PFC = Efficiency factor correction
Previous HydroJet system messages:
- 91 Failure limit switch left (Hydro-Jet)
- 92 Failure limit switch centre (Hydro-Jet)
- 93 Failure limit switch right (Hydro-Jet)
- F1 Failure temperature sensor PT 100 (interruption) (Hydro-Jet)
- F2 Short-circuit temperature sensor PT 100 (Hydro-Jet)